Deploying Edge Clusters
An edge cluster is deployed with the same resources as any storage cluster. This page covers only the steps that differ for edge clusters. The edge-specific requirements are noted in Hardware Requirements and Software Requirements.
Preparing the Hub
The hub runs the control plane with the standalone profile, installed as described in Install Simplyblock Operator, with an admin token for the edge operators:
kubectl create namespace simplyblock
kubectl -n simplyblock create secret generic sb-admin-token \
--from-literal=token="$(openssl rand -hex 32)"
helm install simplyblock-operator simplyblock/simplyblock-operator \
--namespace simplyblock \
--set deployment.profile=standalone \
--set controlplane.local.adminTokenSecretRef=sb-admin-token
The Management API must be reachable from the edge sites, for example, through a LoadBalancer Service with the
selector of the simplyblock-webappapi Service:
kubectl -n simplyblock expose service simplyblock-webappapi \
--name simplyblock-webappapi-edge --type LoadBalancer
Installing the Operator at the Edge
At the edge site, the operator is installed in the managed profile as described in Connecting to an External Control Plane. The token Secret holds the admin token of the hub. An edge cluster also needs the default storage node image, because it has no local control plane that names it:
helm install simplyblock-operator simplyblock/simplyblock-operator \
--namespace simplyblock \
--set deployment.profile=managed \
--set controlplane.managed.endpoint=https://<HUB-MANAGEMENT-API> \
--set controlplane.managed.credentialsSecretRef=cp-token \
--set controlplane.managed.caBundleSecretRef=cp-ca \
--set controlplane.managed.storageNodeImage=<STORAGE-NODE-IMAGE>
Discovery
The discovery follows Create a Storage Cluster. Small edge clusters often run storage on Kubernetes control plane nodes, which the discovery skips by default:
apiVersion: storage.simplyblock.io/v1alpha2
kind: OperatorOps
metadata:
name: discover-edge
namespace: simplyblock
spec:
action: Discover
discover:
configName: edge-draft
enableControlPlaneNodes: true
# Linux block devices instead of NVMe devices:
# enableLogicalBlockDevices: true
# forceJournalDevice: true
With Linux block devices, forceJournalDevice lets the run dedicate one of several equal devices to the journal. The discovery proposes whole disks only. Partitions of a disk shared with the operating system are selected
explicitly, as described in Linux Block Devices.
Draft for a One-Node Edge Cluster
A one-node edge cluster sets clusterMode to Single in the deployment document. The cluster mode lets any
supported erasure-coding scheme run on the one storage node, with every chunk of a stripe on a different device. It
is copied to spec.clusterMode of the StorageCluster when the cluster is created. A cluster cannot be changed to
or from Single afterward.
For a one-worker fleet, the discovery proposes the cluster mode Single and the scheme that the data devices of the
worker carry: 2+1 with three or more devices, 1+1 with two, and 1+0 with one. A device dedicated to the journal does
not count as a data device. Other schemes are chosen by setting the stripe, as long as the worker hands over one data
device per chunk:
kubectl -n simplyblock patch clusterdeploymentconfig edge-draft --type merge -p '{
"spec": {"cluster": {
"name": "edge-site-a",
"clusterMode": "Single",
"stripe": {"dataChunks": 4, "parityChunks": 2}
}}}'
The validation of the document refuses a Single document with more than one storage node, or with a group that
names fewer data devices than the scheme has chunks.
How many device failures the node survives depends on the scheme and on the journal placement, as described in Edge Clusters.
Draft for a Two-Node Edge Cluster
Note
Two-node edge clusters require two-node arbitration support in the control plane, the Simplyblock Operator, and the storage nodes.
A two-node edge cluster sets clusterMode to Dual in the deployment document. The cluster mode lets the
erasure-coding scheme 1+1 run on exactly two storage nodes, which otherwise needs three. It is copied to
spec.clusterMode of the StorageCluster when the cluster is created, together with enableArbitration and
arbitration. For a fleet of exactly two workers, the discovery proposes the cluster mode Dual with 1+1. Other
schemes still need their usual number of storage nodes:
kubectl -n simplyblock patch clusterdeploymentconfig edge-draft --type merge -p '{
"spec": {"cluster": {
"name": "edge-site-b",
"stripe": {"dataChunks": 1, "parityChunks": 1},
"clusterMode": "Dual",
"enableArbitration": true,
"arbitration": {
"holdMs": 2500,
"leaseTtlMs": 1500,
"hostFencing": true
}
}}}'
| Field | Default | Description |
|---|---|---|
clusterMode |
Standard |
Single for one storage node, Dual for two, Standard for three or more. |
enableArbitration |
Off | Enables the arbitration of the hub between the two nodes. |
arbitration.holdMs |
2500 |
How long a node holds write I/O after losing its peer. Must stay below 5 seconds. |
arbitration.leaseTtlMs |
1500 |
Validity of the lease the hub grants each node. Must be shorter than the hold time. |
arbitration.hostFencing |
Off | Lets Kubernetes restart the workloads of a fenced node on the other node. See Host Fencing. |
enableArbitration and arbitration are refused unless clusterMode is Dual.
Host Fencing
With host fencing, Kubernetes follows the fencing decision of the hub: when the hub fences a node, the workloads of that node restart on the other node within seconds. The mechanism is described in Edge Clusters.
Prerequisites
- The NodeHealthCheck operator of the medik8s project. On OpenShift, it is the Node Health Check Operator from
OperatorHub. It is the component that turns the
StorageFencedcondition into a remediation. - All stateful workloads on the two nodes use simplyblock volumes. The out-of-service taint force-detaches every volume of a node, and only simplyblock volumes are fenced. A node with a volume of another CSI driver attached is not remediated unless the remediation template allows it.
- The CSI driver runs on both nodes. Its node plugin publishes the NVMe host NQN of the node as the annotation
storage.simplyblock.io/nvme-host-nqn, which the hub needs to fence the host.
Enabling Host Fencing
Host fencing is set in the deployment document as shown above, or on an existing cluster:
kubectl -n simplyblock patch storagecluster edge-site-b --type merge \
-p '{"spec": {"arbitration": {"hostFencing": true}}}'
The operator passes the setting to the hub and reports the NVMe host NQNs of both Kubernetes nodes. Each storage node
lists two of them, the kernel default (nqn.2014-08.org.nvmexpress:uuid:...) and the simplyblock form
(nqn.2014-08.io.simplyblock:uuid:...):
kubectl -n simplyblock get storagenode \
-o jsonpath='{range .items[*]}{.spec.workerNode}{"\t"}{.status.remediation.reportedHostNQNs}{"\n"}{end}'
Configuring NodeHealthCheck
The remediation template names the simplyblock remediation, and the NodeHealthCheck triggers it on the
StorageFenced condition:
apiVersion: storage.simplyblock.io/v1alpha2
kind: StorageFenceRemediationTemplate
metadata:
name: storage-fence
namespace: simplyblock
spec:
template:
spec:
# Refuse the out-of-service taint while a volume of another CSI driver is
# attached to the node.
allowForeignVolumes: false
---
apiVersion: remediation.medik8s.io/v1alpha1
kind: NodeHealthCheck
metadata:
name: simplyblock-storage-fenced
spec:
# The operator labels the Kubernetes nodes of a storage cluster with the
# cluster's name, whether they are workers or control-plane nodes.
selector:
matchLabels:
io.simplyblock.storagenodeset: edge-site-b
# Required: with the default minHealthy of 51%, one of two nodes is never
# remediated.
maxUnhealthy: 1
unhealthyConditions:
- type: StorageFenced
status: "True"
duration: 2s
remediationTemplate:
apiVersion: storage.simplyblock.io/v1alpha2
kind: StorageFenceRemediationTemplate
namespace: simplyblock
name: storage-fence
| Setting | Value | Why |
|---|---|---|
maxUnhealthy |
1 |
With two nodes, the default minHealthy of 51% blocks the remediation of either node. |
unhealthyConditions[].duration |
2s |
The condition is set only after the hub has fenced the host, so no grace period is needed. |
selector |
The two storage nodes | io.simplyblock.storagenodeset matches control-plane nodes as well, and no arbiter node. |
allowForeignVolumes |
false |
Keeps a node with volumes of another CSI driver from being force-detached unfenced. |
The template is copied into each StorageFenceRemediation when it is created, so a change to the template only applies
to later remediations. The NodeHealthCheck operator creates and deletes StorageFenceRemediation resources with its own
service account. The Simplyblock Operator grants it access through a ClusterRole with the label
rbac.ext-remediation/aggregate-to-ext-remediation: "true", which the chart installs.
Host Connection Settings
Nothing has to be configured on the hosts. The control plane sets the NVMe keep-alive, fast I/O failure, and controller loss timeouts for two-node edge clusters with arbitration, and the CSI driver applies them when it connects a volume.
Approving and Verifying