Failure Domains

A failure domain groups storage nodes that share a common infrastructure dependency: a rack, a cabinet, a power distribution unit, or an availability zone. When failure domains are enabled, simplyblock spreads data chunks, journal copies, and failover paths across the domains so that the loss of one entire domain does not interrupt the availability of the cluster.

Each domain is identified by a label, such as RACK1, AZ2, or HOST1. Simplyblock does not detect the physical topology itself: every storage node is explicitly tagged with the label of the domain it belongs to when it is added to the cluster. The domain is created by the first node carrying a given label, and every later node naming that label joins it.

Internally, each label maps to a cluster-unique integer id, which is what placement and the data plane key off. That id is assigned automatically and does not have to be tracked. It surfaces only in low-level logs and in the failure_domain field of the API, which keeps its integer type for compatibility.

Important

Failure-domain support is a deploy-time decision. It is enabled when the storage cluster is created and cannot be switched on or off for an existing cluster. To gain the feature, a cluster must be redeployed.

What Failure Domains Protect

With failure domains enabled, placement decisions consider the domain tag in four independent dimensions:

  1. Data and parity chunks: The distributed erasure coding spreads the chunks of each stripe across distinct failure domains so that a full domain outage leaves enough chunks to reconstruct all data within the configured erasure coding scheme.
  2. Journal copies: The copies of the high-availability write journal are balanced across domains with a per-domain cap, so that losing a whole domain always leaves enough journal copies to maintain the journal quorum.
  3. Failover paths: The secondary (and, with two parity chunks, tertiary) failover nodes of each logical volume are placed in different failure domains than the primary node wherever possible.
  4. Cluster status: The health assessment of the cluster understands domains. Any combination of node and device outages confined to a single failure domain keeps the cluster serving I/O in a degraded state instead of suspending it.

The Placement Contract

Placement constraints are applied in a fixed priority order: distinct hosts are a hard requirement, distinct failure domains are enforced next, and distinct physical labels are considered last.

For the failover paths, the guaranteed invariant is:

Every logical volume store keeps at least one failover path in a different failure domain than its primary node.

With two failure domains and three paths (primary, secondary, tertiary), it is mathematically impossible to place all three paths in distinct domains. Simplyblock therefore guarantees at least one cross-domain failover path per volume store, which is enough to survive a full domain outage. The remaining paths are placed cross-domain wherever the topology allows it.

At cluster activation, simplyblock arranges the hosts in a round-robin order across the failure domains and derives all secondary and tertiary assignments from this interleaved rotation. On a cluster with equally sized domains, this construction makes every secondary path cross-domain by design.

Balance Rules

Failure-domain placement only works if the domains stay comparable in size. Simplyblock enforces this:

  • At activation, all failure domains must contain an equal number of hosts, and at least two domains must exist.
  • During operation, the host count per domain may never diverge by more than one host (±1 rule). Adding or removing a node is refused if it would unbalance the domains further.
  • Every domain must keep at least two hosts once the cluster holds data.

A cluster with a one-host imbalance stays fully within the availability contract. Exactly one volume store then has a same-domain secondary path, and its tertiary path is still guaranteed to be cross-domain.

Note

Balance is counted in physical hosts, not storage nodes. On multi-socket hosts running two storage nodes, both nodes count as one host and must carry the same failure-domain label. Dedicated secondary nodes are not counted toward the balance.

Failure Domains and Erasure Coding Schemes

The number of failure domains decides two things: whether a cluster can activate with failure domains enabled, and how much simultaneous node or domain loss it absorbs afterward.

Important

Fresh activation requires at least parity chunks + 2 distinct failure domains. Two domains are never enough, at any parity-chunk count. With only parity chunks + 1 domains the layout has no spare host left, so the very next node addition or removal strands a failover path with nowhere valid to go. Below the minimum, activation is refused. Either failure domains have to be disabled, or hosts in further domains have to be added first. A reactivation of an existing layout is only warned about, never blocked.

A stripe consists of data chunks + parity chunks chunks, and placement spreads them as evenly as the available domains allow. How much loss an activated cluster absorbs follows from that spread:

  • With data chunks + parity chunks domains or more, every domain holds at most one chunk of a stripe. The complete loss of up to parity chunks domains at once is then tolerated. This is the same guarantee as running without failure domains, scoped to whole domains instead of individual nodes.
  • With fewer domains than data chunks + parity chunks, at least one domain holds more than one chunk. Each domain contributes at most ⌈(data chunks + parity chunks) / domains⌉ to a risk budget of parity chunks. A domain that already has that many nodes down has spent its whole contribution, so further nodes in the same domain cost nothing extra. A node in a different domain spends a fresh share of the same budget. Any combination is tolerated while the summed contributions stay within parity chunks.
Domains 1+1 2+1 4+1 1+2 2+2 4+2
2 or fewer cannot activate cannot activate cannot activate cannot activate cannot activate cannot activate
3 1 whole domain 1 whole domain 1 node total cannot activate cannot activate cannot activate
4 1 whole domain 1 whole domain 1 node total 2 whole domains 2 whole domains 1 whole domain
5 1 whole domain 1 whole domain 1 whole domain 2 whole domains 2 whole domains 1 whole domain
6+ 1 whole domain 1 whole domain 1 whole domain 2 whole domains 2 whole domains 2 whole domains

"1 whole domain" means every node of one domain, whatever its size, can go down at once and the cluster stays available. The same budget spent as individual nodes, one per domain across that many domains, is tolerated identically. A cell short of a whole domain (4+1 on three or four domains) means only that many individual nodes anywhere in the cluster, not a domain's worth.

The high-availability journal requires at least four journal copies on failure-domain clusters (instead of three), even with a single parity chunk. With three copies and two domains, one domain would hold two copies and its loss would break the journal quorum.

Domain Membership Is Immutable

A host's failure domain cannot be changed while the host is part of the cluster. Moving a host between domains requires removing the node, restoring the domain balance, and re-adding it with the new failure-domain label. This prevents accidental topology changes that would silently invalidate the placement of existing data.

When to Remove a Node

Node removal takes a host out of the cluster permanently. It serves two purposes: retiring a failed host that is not coming back, and shrinking a cluster that has more storage nodes than it needs. A node that is offline or unreachable can still be removed, so removal is the intended way to resolve a dead host rather than a last resort.

Leaving a dead node in the cluster is the case to avoid. Domain balance counts every host that has not been removed, whatever its state, so a dead node still occupies its domain's slot while serving nothing. The cluster stays degraded, and the balance rules then close the door behind it:

  • The first dead host in a domain can still be removed. Its domain drops to one host below the others, which the ±1 rule permits.
  • If a second host in that same domain fails before the first is removed, only one of the two can go. Removing the second would leave that domain two hosts below the others and, on a three-host domain, below the two-host floor. Admission refuses it.

At that point the degradation cannot be cleared by removal at all, and hosts have to be added before the cluster can be repaired. Remove a failed host promptly, then restore the balance one of two ways:

  • Add a replacement host in the same failure domain, returning the split to what it was.
  • Rebalance by removing hosts from the other domains until every domain is within ±1 again.

The same reasoning applies to planned shrinking: reduce the domains evenly rather than emptying one, so the cluster never sits closer to the floor than it has to.

A removal is admitted only when all of the following hold:

  • The node holds no volumes and no snapshots. Migrate or delete them first; removal does not move them.
  • The resulting per-domain host split stays within the ±1 rule and keeps at least two hosts per domain.
  • Every failover path the node hosts for another volume store has a valid host-disjoint target to move to, after the splice fallback described in The Placement Contract.
  • The cluster has enough node headroom above data chunks + parity chunks to absorb the loss, counting hosts that are already not online.

Journal Copy Replacement on Removal

Removing a node affects every journal redundancy set that referenced the departed node's journal copy. One replacement member is picked per set, and every host running a local instance of that set applies the same decision, so the membership stays identical on all of them.

The replacement is picked with the same domain-balance goal as the original placement. A candidate from the same failure domain as the departed node is preferred, which leaves the set's domain distribution as it was instead of reshuffling it. The preference is best-effort, not a requirement: if no same-domain candidate is free, a cross-domain one is used, and the removal is never blocked over it. Failover-path relocation works in the opposite direction (see The Placement Contract), where a cross-domain target is sometimes mandatory and the removal is refused without one.

Recovery Behavior

Failure domains also change how the cluster recovers from large outages:

  • An outage confined to one domain keeps the cluster degraded but serving, as long as that domain's worst-case contribution fits the parity budget of the sizing table above. The cluster is not suspended.
  • With two parity chunks and at least data chunks + parity chunks domains, the loss of one entire domain plus one further node or device outage in exactly one other domain is tolerated as well.
  • When a whole domain returns from an outage (for example, after a rack power loss), its nodes are restarted in parallel instead of strictly one-by-one, substantially shortening the recovery of large domains.

For operating instructions (cluster creation, node addition, node removal, and the expansion rules), see Managing Failure Domains. For Kubernetes-based deployments, failure domains are assigned through the Simplyblock Operator. See the Operator Reference.